• 4F Building4, Han's Laser Industry Park, 128 Chongqing Street, Fuyong, Bao'an District
  • Shenzhen , Guangdong,
  • Çin
  • Tel:+86 0755-27333701
  • Faks: ---.---.-----
  • Web adresi:

5-axis Laser Micromachining System

Mercek merkezleme donanımları

$ 500 USD / Parça

Yeni

Mevcut değil

Mevcut değil

Sormak

Ürün tanımı

The ordinary laser drilling system can only process the taper hole, and can not achieve the standard straight hole and inverted cone hole processing. Besides the standard straight hole and the taper hole processing, the 5-axis laser micro machining system can also process the inverted cone hole, which greatly expands the laser drilling applications. With different wavelengths and super fast lasers, the thermal effect of drilling is small and the surface treatment is smooth. Only by making the processing materials unlimited, has been applied to drilling and processing in all walks of life.

Key Features Of 5-axis Laser Micromachining System

In order to ensure accurate synchronization, it is necessary to process the position data of each axis under the same processor and control clock. This design uses high speed digital chip FPGA to achieve

The positioning accuracy of the galvanometer will directly affect the machining accuracy of the equipment, and the factors affecting the positioning accuracy of the galvanometer mainly include the accuracy of the galvanometer feedback system, controller and the accuracy of correction.

The self-developed 24-bit high-precision encoder, combined with the high bandwidth driver based on PID and feedforward controller, improves the control accuracy of the system.

Adopt high-precision CNC machine tool to fix and clamp important structural parts at one time to ensure high-precision installation of galvanometer motion module.

Specifications Of 5-axis Laser Micromachining System

Working field size (Diameter, Depending On Nozzle Opening) mm φ0.025mm to φ1mm

Maximum Focus Range In Z Direction mm ±1mm

Entrance Beam Diameter (1/e2) mm 10mm

Focus Diameter In Image Field (1/e²) for M² = 1 um 25um

Maximum Angle Of Incidence 18°

Precession Frequency HZ 200-600HZ(12000-36000rpm)

Objective Focal Length mm 50mm

Repeatability um ≤0.5um=

Theoretical Resolution Of Incidence Angle urad 2urad

Dimension(L*W*H) mm 601×280×274

Weight Kg 23.5

Hans scanner provides galvo head, galvanometer scanner, galvano scanner and etc. If you want to know more, please contact us.