2600mah Li-Ion Battery Product Details:
NO. Items Specifications
1 Model INR18650-2600
2 Can Material Ni-Iron
3 Rated Capacity 2600 mAh(0.2C5A)
Min. Capacity 2550 mAh(0.2C5A)
4 Nominal Voltage 3.7V
5 Max. Charge Voltage 4.2 V
6 Discharge Cut-off Voltage 2.75V
7 Max. Charge Current 1 C5A
8 Standard Discharging Current 0.2 C5A
9 Max. Continuous Discharge Current 13 A
10 Max. Pulse Discharge Current 30A( 2s pulse )
11 Max. Diameter(include PET) ≤18.40 mm
12 Max. Height (include PET) ≤65.50mm
13 Weight (Approx.) 44.0±1.0g
14 Impedance (Max. at 1000Hz、charged status) ≤ 18 mΩ
15 Charge Method (CC/CV) Standard 0.5 C5A×6hrs
Quick 1 C5A×1.5hrs.
16 Operating Temperature Charge 0℃~45℃ 32oF~113oF
Discharge -20℃~60℃ -4oF~140oF
Storage -20℃~45℃ -4oF~113oF
Characteristic of custom 2600mAh Li-ion battery
Without special instructions, the following tests should be done under the condition of : temperature(23℃±3℃), atmospheric pressure (86KPa~106KPa), relative humidity (45%~85%), and the tests should be done within two weeks after receiving the products.
the definitions of some nomenclatures of this specification
standard Charge: Charge with current 0.2C5A to limit charge voltage under the condition of23℃±3℃ surrounding temperature, then change to charge with constant voltage till the current less than or equal to 0.02C5A.
Electrical Characteristic for power tool rechargeable Li-ion battery supplier
NO. Item Standard Test Method
1 Discharge rate capabilities A)1 C5A ≥100% B)10 C5A ≥95% C)15 C5A ≥90% Standard charged under the condition of normal atmospheric pressure and the environmental temperature of 23℃±3℃ and45%~85%RH, then rest for 30mins and discharge at1C5A、5 C5A、10 C5A to the discharge cut-off voltage respectively. Charge/discharge cycle can be conducted for 3times before meeting the Standards(the same below)
2 capacity retention and recovery Residualcapacity≥94% Recoverablecapacity≥*98% Standard charged under the condition of normal atmospheric pressure and the environmental temperature of 23℃±3℃, Stored for 28 days, then discharge at 0.2 C5A to 2.75Vmeasuring residual capacity; Then standard charge/discharge measure recoverable capacity.
3 Low Temperature Performance discharge capacity≥85% rated capacityno distortion and no rupture The cell shall be charged in accordance with the standard charge. Then stored in the temperature of -10℃±1℃ for4h, Discharge at the constant current of 0.2C5A down to the end-of-discharge voltage 2.75V.
4 Cycle Life ≥300cycles Charge: The cell shall be charged in accordance with RapidCharge condition. rest for 10mins.Discharge: 10C5A discharge to 2.75V, one cycle is finished, then rest for 30mins. Then repeat above steps, when capacity is less than 80% of initial capacity, the battery life is over.
Safety Characteristic of e-bike cylindrical power lithium-ion batteries
NO. Item Standard Test Method
1 Overcharge No fire、No explosion After standard charge, rest for 10mins; then charge at constant current of 3C5A to 10V.(or charge at 3C5A for 90mins).
2 Forced discharge No fire、No explosion The battery to be discharged with standard discharging condition, Inverse charge current =1C5A;time: ≥ 90mins
3 Short Circuit test No fire、 No explosion The battery to be fully charged with standard charging condition, and short the positive and negative terminals
with wire resistance ≤50mΩ.Tests are to be conducted at 23℃±3℃ and at 55℃ ±5℃, keep 24h or case temperature decline to 20% of the max temperature ,test is over.
4 Crush test No fire、No explosion A battery is crushed between two flat surfaces. The applied force is 13 kN±1kN by hydrocylinder, Once the maximum pressure has been obtained or voltage decrease to 1/3 of nominal voltage sharply, then release pressure.
5 Shock test No fire、No explosion The full charged battery is fixed on shock table, to force a cert