• No. 8, Xingyuan Road, Huangqiao Industrial Park, Taixing, Jiangsu, China
  • Taixing, Jiangsu, 225411
  • Trung Quốc
  • Điện thoại:86-0512-58566663
  • Fax:86-0512-58566663
  • Url:

INR18650-2200mAh battery

Sản phẩm hóa chất

THEO YÊU CẦU

Mới

Không có sẵn

Không có sẵn

Hỏi

Mô tả sản phẩm

INR18650-2200mAh battery,2000mAh Li-ion battery supplier,lithium ion battery for power tool,power tool lithium ion battery supplier

2200mAh Li-ion battery Product Details:

NO. Items Specifications

1 Model INR18650-2200

2 Can Material Ni-Iron

3 Rated Capacity 2200 mAh(0.2C5A)

4 Nominal Voltage 3.7V

5 Max. Charge Voltage 4.2 V

6 Discharge Cut-off Voltage 2.75V

7 Max. Charge Current 1 C5A

8 Standard Discharging Current 0.5 C5A

9 Max. Continuous Discharge Current 11 A

10 Max. Pulse Discharge Current 30A( 2s pulse  )

11 Max. Diameter(include PET) ≤18.40 mm

12 Max. Height (include PET) ≤65.50mm

13 Weight (Approx.) 44.0g

14 Impedance (Max. at 1000Hz、charged status) ≤ 18 mΩ

15 Charge Method (CC/CV) Standard 0.2 C5A×5hrs

Quick 1 C5A×2.5hrs.

16 Operating Temperature Charge 0℃~45℃ 32oF~113oF

Discharge -10℃~60℃ -4oF~140oF

Storage -20℃~45℃ -4oF~113oF

Characteristic  of 2200mAh Li-ion cylindrical battery

Without special instructions, the following tests should be done under the condition of : temperature(23℃±3℃), atmospheric pressure (86KPa~106KPa), relative humidity (45%~85%), and the tests should be done within two weeks after receiving the products.

the definitions of some nomenclatures of this specification

standard Charge: Charge with current 0.2C5A to limit charge voltage under the condition of23℃±3℃ surrounding temperature, then change to charge with constant voltage till the current less than or equal to 0.02C5A.

Electrical Characteristic  for Cylindrical Rechargeable Electric vehicle li-ion Battery

NO. Item Standard Test Method

1 Discharge rate capabilities A)1 C5A ≥97% B)5 C5A ≥95% Standard charged under the condition of normal atmospheric pressure and the environmental temperature of 23℃±3℃ and45%~85%RH, then rest for 30mins and discharge at1C5A、5 C5A、10 C5A to the discharge cut-off voltage respectively. Charge/discharge cycle can be conducted for 3times before meeting the Standards(the same below)

2 capacity retention and recovery Residualcapacity≥94 %

Recoverablecapacity≥*98% Standard charged under the condition of normal atmospheric pressure and the environmental temperature of 23℃±3℃, Stored for 28 days, then discharge at 0.2 C5A to 2.50Vmeasuring residual capacity; Then standard charge/discharge measure recoverable capacity.

       3 Low TemperaturePerformance discharge capacity≥85% rated capacityno distortion and no rupture The cell shall be charged in accordance with the standard charge. Then stored in the temperature of -10℃±1℃ for4h, Discharge at the constant current of 0.2C5A down to the end-of-discharge voltage 2.750V.

4 Cycle Life Charge: The cell shall be charged in accordance with RapidCharge condition. rest for 10mins.Discharge : 5C5A discharge to 2.75V, one cycle is finished, then rest for 30mins. Then repeat above steps, when capacity is less than 80% of initial capacity, the battery life is over.

Safety Characteristic of bicycle 18650 battery

NO. Item Standard Test Method

1 Overcharge No fire、No explosion After standard charge, rest for 10mins; then charge at constant current of 3C5A to 10V.(or charge at 3C5A for 90mins). 

2 Forced discharge No fire、No explosion The battery to be discharged with standard discharging condition, Inverse charge current =1C5A;time: ≥  90mins 

3 Short Circuit test No fire、 No explosion The battery to be fully charged with standard charging condition, and short the positive and negative terminals 

       with wire resistance  ≤50mΩ.Tests are to be conducted at 23℃±3℃  and at 55℃ ±5℃, keep 24h or case temperature decline to 20% of the max temperature ,test is over. 

4 Crush test No fire、No explosion A battery is crushed between two flat surfaces. The applied force is 13 kN±1kN by hydrocylinder, Once the maximum pressure has been obtained or voltage decrease to 1/3 of nominal voltage sharply, then release pressure. 

5 Shock test No fire、No explosion The full charged battery is fixed on shock table, to force a certain shock to three mutual vertical direction, in initial